Please use this identifier to cite or link to this item:
https://wslhd.intersearch.com.au/wslhdjspui/handle/1/6673
Title: | A Randomized Controlled Trial of Cold Snare Polypectomy Technique: Technique Matters More Than Snare Wire Diameter |
Authors: | Sidhu, Mayenaaz;Forbes, Nauzer;Tate, David J.;Desomer, L.;Lee, Eric Y. T.;Burgess, Nicholas;van Hattem, Arnout;Mcleod, Duncan;Cheng, E.;Cartwright, S.;Schell, A.;Hilsden, Robert J.;Heitman, Steven J.;Bourke, Michael J. |
WSLHD Author: | Sidhu, Mayenaaz;Forbes, Nauzer;Tate, David J.;Lee, Eric Y. T.;Burgess, Nicholas G.;van Hattem, Arnout;Mcleod, Duncan;Hilsden, Robert J.;Heitman, Steven J.;Bourke, Michael J. |
Issue Date: | 2022 |
Citation: | American Journal of Gastroenterology 117(1):100, 2022 |
Abstract: | INTRODUCTION: Cold snare polypectomy (CSP) is safe and effective for the removal of small adenomas (<=10 mm); however, reported incomplete resection rates (IRRs) vary. The optimal CSP technique, where a wide margin of normal tissue is resected around the target lesion, and snare design have both been hypothesized to reduce the IRR after CSP. We sought to investigate the efficacy of a thin-wire versus thick-wire diameter snare on IRR, using the standardized CSP technique. METHODS: This was an international multicenter parallel design randomized trial with 17 endoscopists of varying experience (NCT02581254). Patients were randomized in a 1:1 ratio to the use of a thin-wire (0.30 mm) or thick-wire (0.47 mm) snare for CSP of small (<=10 mm) colorectal polyps. The primary end point was the IRR as determined by the histologic assessment of the defect margin after polypectomy. RESULTS: Over 52 months to January 2020, 1,393 patients were eligible. A total of 660 patients with polyps (57.4% male) were randomized to a thin-wire (n = 339) or thick-wire (n = 321) snare. The overall IRR of the cohort was 1.5%. There was no significant difference in the IRR between the thin- and thick-wire arms; relative risk-0.41, 95% CI (0.11-1.56), P = 0.21. No significant differences were observed in the rate of adverse events. DISCUSSION: In this multicenter randomized trial, CSP is safe and effective with very low rates of incomplete resection independent of the diameter of the snare wire used. This suggests that the optimal operator technique is more important than the snare design alone in minimizing residual adenoma after CSP. |
URI: | https://wslhd.intersearch.com.au/wslhdjspui/handle/1/6673 |
DOI: | https://dx.doi.org/10.14309/ajg.0000000000001554 |
Journal: | American Journal of Gastroenterology |
Type: | Journal Article |
Study or Trial: | Multicenter Study Randomized Controlled Trial Research Support, Non-U.S. Gov't |
Department: | Gastroenterology and Hepatology |
Facility: | Auburn Westmead |
Keywords: | Biopsy Colectomy Colonic Polyps Colonoscopy Margins of Excision Microsurgery |
Appears in Collections: | Auburn Hospital |
Files in This Item:
There are no files associated with this item.
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.