WSLHD
Skip navigation
Please use this identifier to cite or link to this item: https://wslhd.intersearch.com.au/wslhdjspui/handle/1/8969
TitleEffect of syringe underfilling on the quality of venous blood gas analysis
Authors: Lippi, G.;Pighi, L.;Tosi, M.;Vettori, M.;Celegon, G.;Favaloro, Emmanuel J.;Salvagno, G. L.
WSLHD Author: Favaloro, Emmanuel J.
Issue Date: 2024
Citation: Diagnosis 11(1):91-96, 2024
Abstract: OBJECTIVES: There is limited information on the influence of collecting small amounts of blood on the quality of blood gas analysis. Therefore, the purpose of this study was to investigate the effects of different degrees of underfilling of syringes on test results of venous blood gas analysis. METHODS: Venous blood was collected by venipuncture from 19 healthcare workers in three 1.0mL syringes for blood gas analysis, by manually aspirating different volumes of blood (i.e., 1.0, 0.5 and 0.25mL). Routine blood gas analysis was then immediately performed with GEM Premier 5,000. The results of the two underfilled syringes were compared with those of the reference syringe filled with appropriate blood volume. RESULTS: The values of most assayed parameters did not differ significantly in the two underfilled syringes. Statistically significant variations were found for lactate, hematocrit and total hemoglobin, the values of which gradually increased as the fill volume diminished, as well as for sodium concentration, which decreased in both insufficiently filled blood gas syringes. The bias was clinically meaningful for lactate in syringe filled with 0.25mL of blood, and for hematocrit, total hemoglobin and sodium in both syringes containing 0.5 and 0.25mL of blood. CONCLUSIONS: Collection of smaller volumes of venous blood than the specified filling volume in blood gas syringes may have an effect on the quality of some test results, namely lactate, hematocrit, total hemoglobin and sodium. Specific indications must be given for standardizing the volume of blood to be collected within these syringes. Copyright 2023 Walter de Gruyter GmbH, Berlin/Boston.
URI: https://wslhd.intersearch.com.au/wslhdjspui/handle/1/8969
DOI: https://dx.doi.org/10.1515/dx-2023-0096
Journal: Diagnosis
Type: Journal Article
Department: Haematology
Facility: Westmead
Keywords: Syringes
Blood Gas Analysis
Lactic Acid
Sodium
Hemoglobins
Appears in Collections:Westmead Hospital 2019 - 2024

Files in This Item:
There are no files associated with this item.


Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.